Model number | HJ31-30 | HJ31-50 | HJ31-100 / HJ31-100A | HJ31-200 | HJ31-500 | HJ31-1000 | HJ31-1500 | ||||||||
Maximum load (kg) | 30 | 50 | 100 | 200 | 500 | 1001 | 1500 | ||||||||
Mounting platform size | 500*500 | 600*600 | 700*700 | 800*800 | 1000*1000 | 1200*1200 | 1500*1500 | ||||||||
Acceleration range (g) | 0.5-100 | 0.5-50 | |||||||||||||
Acceleration accuracy (%) | <±3 | ||||||||||||||
Installation calculation radius (mm) | 1000 | 1200 | 1650 | 2150 | 2600 | 3000 | 5400 | 6250 | |||||||
Maximum turning diameter (mm) | 2500 | 3000 | 4000 | 5000 | 6000 | 7000 | 12000 | 14000 | |||||||
Startup/shutdown time (Min) | <3 | <5 | <8 | <10 | |||||||||||
Continuous working time (min) | 60 | 30 | |||||||||||||
Pit diameter (mm) | Ф3000 | Ф3500 | Ф4500 | Ф5500 | Ф7000 | Φ8500 | Φ14000 | Φ16000 | |||||||
Collecting ring device | Optional according to user requirements | ||||||||||||||
Table weight (kg) | 2500 | 4000 | 5000 | 5500 | 7000 | 8000 | 10000 | 12000 | |||||||
Power supply | AC380V±10% 30KVA | AC380V+10%45KVA | AC380V±10% 60KVA | AC380V±10 % 75KVA | AC380V+10 % 110KVA | AC380V±10% 150KVA | AC380V±10%500KVA | AC380V±10% 800KVA | |||||||
Measurement control system | Full closed loop digital network (remote) automatic control + manual control | ||||||||||||||
remarks | Connecting device and control precision can be configured according to relevant standards or user requirements | ||||||||||||||
Working environment | Temperature 0-40℃; Humidity < 80% dew free | ||||||||||||||
standard | GB/T 2423 GJB 150A GJB1027 GJB360BMIL-STD-810F IEC68-2-7 |